SES-2 Enclosure Management
The introduction of Serial Attached SCSI (SAS) as the most recent evolution of SCSI required to re-define the related standard for enclosure management, called SCSI Enclosure Services . SES-2, or SCSI Enclosure Management 2 first revision was introduced in 2002 and is now at revision 20.
SES-2 SCSI Enclosure Services (SES) permit the management and sense the state of power supplies, cooling devices, LED displays, indicators, individual drives, and other non-SCSI elements installed in an enclosure. SES2 alerts users about drive, temperature and fan failures with an audible alarm and a fan failure LED.
==SES-2 Commands==
The SES-2 command set uses the SCSI SEND DIAGNOSTIC and RECEIVE DIAGNOSTIC RESULTS commands to obtain configuration information for the enclosure and to set and sense standard bits for each element installed in the enclosure.
The SEND DIAGNOSTIC command is used to send control information to internal or external LED indicators or to instruct one enclosure element to change its state or perform an operation.
The application client has two mechanisms for accessing the enclosure service process:
:a) Directly to a standalone enclosure services process, for example an enclosure controller chip. SCSI conditions communicated directly include hard reset, logical unit Reset and I_T nexus loss.
:b) Indirectly through a LUN of another peripheral device – for example a drive within the enclosure. The drive will communicate with the Enclosure through the Enclosure Services Interface. In this case the only SCSI device condition communicated through the LUN is hard reset.